SDM-2020 Satellite Demodulator Revision 4
Front Panel Operation MN/SDM2020D.IOM
6–36
(FAULT LABEL)
-----------
Displays the stored date and time of a fault or alarm, such as:
Battery/Clock
-12 Volt Supply
+12 Volt Supply
+5 Volt Supply
Controller
LNB
Function Select: Stored FLTS/ALMS: UNAVAL SECONDS
UNAVAL SECONDS 0
STORED TIME/DATE
A fault is indicated if the Reed-Solomon Codec could not correct bit errors in one block
of serialized data in any given second.
Function Select: Stored FLTS/ALMS: CLEAR??
CLEAR??
STORED FAULTS
To clear the currently logged stored faults, press <ENTER> when the “Clear Stored
Faults/YES?” selection is displayed.
6.1.9 Function Select: Utility