LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–31
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Unread Stored
Statistics
Returns the oldest 5 unread stored statistics entries in the reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body, where:
Sub-body= ddmmyyhhmmssaaa.abbb.bccc.cdd.ddefghhh.hiii.i
ddmmyy = day/month/year
hhmmss = hour:minute:second
aaa.a = Operating Temperature (I.E. +40.0)
bbb.b = Amp Temperature (I.E. +40.0)
ccc.c = RF Power output
dd.dd = Attenuation Setting
e = Amp On/Off
f = Mute On/Off
g = Online/Offline Status
hhh.h = LNB Current (mA)
iii.i = BUC Tuning Voltage
If there are less than 5 entries to be retrieved, the remaining positions are padded with zeros. If there are no new
entries, the response is RNS*.
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-body
(See Description of
Arguments)
Returns the unit’s 9 digit serial number in the form of xxxxxxxxx.
Example: <1/RSN?’cr’
>0001/RSN=072282040’cr’’lf’
(See Description of
Arguments)
Status
alpha- numeric
Returns the utility status of the unit.
Example: <1/RUS=’cr’
>0001/RUS=’cr’
ADR=0001’cr’
BDR=09600’cr’
REF=087’cr’’lf’ (see Note)
Note: REF will only appear if a reference oscillator is installed.
(See Description of
Arguments)