Comtech-ef-data UT-4579 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Comtech-ef-data UT-4579. Comtech EF Data UT-4579 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
UT-4579
X-Band Up Converter
Installation and Operation Manual
Part Number MN/UT4579.IOM
Rev. 0
Przeglądanie stron 0
1 2 3 4 5 6 ... 99 100

Podsumowanie treści

Strona 1 - UT-4579

UT-4579 X-Band Up Converter Installation and Operation Manual Part Number MN/UT4579.IOM Rev. 0

Strona 2

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 vi C.1 Applications...

Strona 3 - Errata A

2114 West 7th Street Tempe Arizona 85281 USA 480 • 333 • 2200 Phone 480 • 333 • 2161 FAX

Strona 4

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 vii Figures Figure 1. Front Panel...

Strona 5

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 viii Tables Table 1. UT-4579 Up Converter Specifications ...

Strona 6 - CUSTOMER SUPPORT

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 ix ABOUT THIS MANUAL This manual provides installation and operation information for the Com

Strona 7 - Table of Contents

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 x REPORTING COMMENTS OR SUGGESTIONS CONCERNING THIS MANUAL Comments and suggestions regardin

Strona 8

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 xi SAFETY COMPLIANCE EN 60950 Applicable testing is routinely performed as a condition of m

Strona 9

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 xii WARRANTY POLICY This Comtech EF Data product is warranted against defects in material an

Strona 10 - Preface Rev. 0

1 Chapter 1. Introduction UT-4579 Up Converter 1.1 OVERVIEW This manual provides instructions on the installation, operation and maintenance of the

Strona 11 - Figures

UT4579 X-Band Up Converter MN/UT4579.IOM Introduction Rev. 0 2 All operator controls, indicators and displays for local and remote operation are loc

Strona 12

UT4579 X-Band Up Converter MN/UT4579.IOM Introduction Rev. 0 3 1.3 PHYSICAL CONFIGURATION Figure 4 is a top view layout of a UT-4579 Up Converter ch

Strona 14 - EMC COMPLIANCE

UT4579 X-Band Up Converter MN/UT4579.IOM Introduction Rev. 0 4 1.3.1 FRONT PANEL DISPLAY The front panel display is a two line, 24-character, LCD di

Strona 15 - EN 60950

UT4579 X-Band Up Converter MN/UT4579.IOM Introduction Rev. 0 5 1.4 SPECIFICATIONS Table 1. UT-4579 Up Converter Specifications Characteristic Spe

Strona 16 - WARRANTY POLICY

UT4579 X-Band Up Converter MN/UT4579.IOM Introduction Rev. 0 6 Characteristic Specification Group Delay Linear Group Delay Parabolic Delay Group

Strona 17 - Chapter 1. Introduction

UT4579 X-Band Up Converter MN/UT4579.IOM Introduction Rev. 0 7 1.5 DIMENSIONAL ENVELOPE (UT-4579) Dimensions are shown in both inches and centimeter

Strona 18 - Figure 1. Front Panel

UT4579 X-Band Up Converter MN/UT4579.IOM Introduction Rev. 0 8 NOTES:

Strona 19 - 1.3 PHYSICAL CONFIGURATION

9 Chapter 2. Installation Unpacking and Inspection 9 Rack Mount Installation 9 Prime Power Connection 10 Cable Connections 10 2.1 UNPACKING AND

Strona 20 - 1.3.3 PRIME POWER SWITCH

UT4579 X-Band Up Converter MN/UT4579.IOM Installation Rev. 0 10 2.3 PRIME POWER CONNECTION The detachable power cord mates with the AC Prime power r

Strona 21 - 1.4 SPECIFICATIONS

UT4579 X-Band Up Converter MN/UT4579.IOM Installation Rev. 0 11 2.4.2 EIA-485/EIA-232C INTERFACE (COM 1), CONNECTOR J1 The EIA-485/EIA-232C Interfac

Strona 22 - Introduction Rev. 0

UT4579 X-Band Up Converter MN/UT4579.IOM Installation Rev. 0 12 2.4.3 HIGH SPEED BUS (HSB), CONNECTOR J3 The High Speed Bus connector, J3, is 25 pin

Strona 23

UT4579 X-Band Up Converter MN/UT4579.IOM Installation Rev. 0 13 PowerSupplyReferenceOscillatorFineStepModuleSumLoopModuleMonitor & Control Assem

Strona 24

Filename: T_ERRATA 1 Errata A Comtech EF Data Documentation Update Subject: Changes to Table 1. UT4579 X-Band Up Converter Specifications Date:

Strona 25 - Chapter 2. Installation

UT4579 X-Band Up Converter MN/UT4579.IOM Installation Rev. 0 14 J5RFIFJ3 HSBJ4IOM-XXIFOUTPUTRFINPUTNOCONNECTION Figure 7. Non-Redundant Converter C

Strona 26 - 2.4 CABLE CONNECTIONS

15 Chapter 3. System Operation Overview 15 Switching Power ON 17 Operation 17 3.1 OVERVIEW This chapter contains instructions for operating the co

Strona 27 - Installation Rev. 0

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 16 Table 8. Operating Functions – Front Panel Item Reference Designation Functio

Strona 28

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 17 3.2 SWITCHING POWER ON Before turning the Prime Power Switch to the ON position

Strona 29

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 18 LEGENDDISPLAYKEY-PADENTCLR---------SELECT-----------MONITOR-STATUS-MENU---------

Strona 30 - RF OUTPUT

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 19 FREQ= 79XX.XXX-MHz-----ATTN=-10.00-DB---Tx=OFF-ENTER---------SELECT-------------

Strona 31 - Chapter 3. System Operation

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 20 ENTER---------SELECT-------------CONFIGURATION-MENU----ENTRY-MODE-=-REMOTE----CO

Strona 32 - SW VER 4.06 SN45793513

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 21 ENTER---------SELECT-------------CONFIGURATION-MENU----ENTRY-MODE-=-REMOTE----CO

Strona 33 - 3.3 OPERATION

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 22 ENTER---------SELECT--------------PRE-SELECT-MENU-----PROGRAM-PRE-SELECT-XX--XXX

Strona 34 - --CURRENT-FAULTS-MENU

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 23 ENTER---------SELECT------------CURRENT-FAULTS-MENU--SYNTH-FAULTS:-SUM-LD=OK-FIN

Strona 36

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 24 ENTER---------SELECT----------UTILITY-FUNCTIONS-MENU--DISPLAY-CONTRAST-=-XX--DIS

Strona 37

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 25 3.3.1 CONVERTER COMMANDS The converter commands are in a tree structured menu fo

Strona 38 - ---MONITOR-STATUS-MENU

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 26 3.3.2 CONFIGURATION FUNCTIONS MENU The Configuration Functions are as follows:

Strona 39 - ---CURRENT-FAULTS-MENU

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 27 3.3.3.2 CONFIGURE CONVERTER TO PRE-SELECT This command allows the local operator

Strona 40 - -UTILITY-FUNCTIONS-MENU

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 28 3.3.5.3 SYNTHESIZER FAULTS Displays the synthesizer faults:  Sum Loop Detect.

Strona 41 - 3.3.1 CONVERTER COMMANDS

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 29 3.3.7 UTILITY FUNCTION MENU The local operator can input commands to the followi

Strona 42 - System Operation Rev. 0

UT4579 X-Band Up Converter MN/UT4579.IOM System Operation Rev. 0 30 NOTES:

Strona 43

31 Appendix A. Redundant System Operation Overview 31 Backup Converter 32 Redundant Configurations 33 A.1 OVERVIEW The Comtech EF Data UT-4579 Up

Strona 44

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 32 A.2 BACKUP CONVERTER The "Daisy Chain" terminates in the bac

Strona 45 - 3.3.7 UTILITY FUNCTION MENU

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 33 A.3 REDUNDANT CONFIGURATIONS Comtech EF Data UT-4579 Up Converters can

Strona 46

Copyright © Comtech EF Data, 2001. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, (480) 333

Strona 47 - Operation

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 34 LP OUTLP IN RFJ9J5IFJ4IOM-XXLP OUTJ3 HSBJ4 J6 J8IFJ5LP INJ7RFOUTPUTRFI

Strona 48 - A.2 BACKUP CONVERTER

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 35 IF InUp Converter - IOM(Backup Unit)Up Converter - TSEQM(On line)RF Ou

Strona 49 - A.3 REDUNDANT CONFIGURATIONS

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 36 IF INPUT #2IF INPUT #1(PRIORITY)UP CONVERTER(BACKUP UNIT)RF OUTPUT #2R

Strona 50

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 37 BACKUP CONVERTER (BU)CONVERTER No. 1CONVERTER No. 2CONVERTER No. NRFOU

Strona 51

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 38 RFOUTPUT#3RFOUTPUT#NRFOUTPUT#4RFOUTPUT#2RFOUTPUT#1IFINPUT#NIFINPUT#1I

Strona 52

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 39 A.4 REDUNDANT SYSTEM CONFIGURATION A.4.1 INITIAL CONFIGURATION Redunda

Strona 53

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 40 A.4.2 AUTOMATIC CONFIGURATION VERIFICATION The backup converter has a

Strona 54

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 41 Figure 30 depicts the front panel displays after power has been turned

Strona 55 - A.4.1 INITIAL CONFIGURATION

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 42 A.4.3 MANUAL CONFIGURATION/VERIFICATION Figure 31 shows the system wit

Strona 56

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 43 Figure 32 shows the front panel displays after the backup has forced c

Strona 57 - -CONVERTER-#-03

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 ii CUSTOMER SUPPORT Contact the Comtech EF Data Customer Support Department for:  Product

Strona 58

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 44 A.4.4 OFFSET ADJUSTMENT The offset is used to compensate for cable and

Strona 59 - -ACTIVATE-BACKUP:-FORCED

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 45 To remove a “Backup” converter for repair the following procedure mus

Strona 60 - A.4.4 OFFSET ADJUSTMENT

UT4579 X-Band Up Converter MN/UT4579.IOM Redundant System Operation Rev. 0 46 NOTES:

Strona 61

47 Appendix B. Remote Control Remote Control Overview 47 Protocol 48 Access Methods 49 Addresses 50 Message Structure 51 Command / Response Pairs

Strona 62

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 48 B.2 PROTOCOL B.2.1 TRANSMISSION MODE The transmission mode is half duplex implemen

Strona 63 - Appendix B. Remote Control

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 49 B.3 ACCESS METHODS Converters may be accessed directly by using a physical address

Strona 64 - B.2 PROTOCOL

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 50 B.3.2.2 EIA-232C To control by using the EIA-232C interface, one EIA-232C port on

Strona 65 - B.3 ACCESS METHODS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 51 B.5 MESSAGE STRUCTURE The structure of either a Command , Response or Error Messag

Strona 66 - B.4 ADDRESSES

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 52 B.5.5 ERROR RESPONSE If a converter cannot execute a Command or detects a protocol

Strona 67 - B.5 MESSAGE STRUCTURE

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 53 B.6 COMMAND / RESPONSE PAIRS B.6.1 UTILITY COMMANDS B.6.1.1 TIME Command Details

Strona 68 - B.5.6.2 RESPONSE ENDING

iii Table of Contents Customer Support...

Strona 69 - B.6 COMMAND / RESPONSE PAIRS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 54 B.6.1.5 LCD CONTRAST The default is 15. Command Details Set Contrast: <DEV/CO

Strona 70 - B.6.1.6 LCD BRIGHTNESS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 55 B.6.1.9 EQUIPMENT TYPE Equipment Type is a command that retrieves the model number

Strona 71 - B.6.1.9 EQUIPMENT TYPE

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 56 B.6.1.11 APPLICATION IDENTIFICATION The Application Identification (AID) command a

Strona 72 - B.6.2.1 F

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 57 B.6.2.2 ATTENUATOR The default is 10 dB. Command Details Set Attenuator: <DEV

Strona 73 - B.6.2.4 MUTE

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 58 B.6.2.5 AUTO FAULT RECOVERY The converter output is automatically muted in the eve

Strona 74 - B.6.2.7 DISPLAY ALL PRESETS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 59 B.6.2.8 CLEAR PRESET This command is used to clear a preset number. Command Detai

Strona 75 - B.6.3.1 REDUNDANCY MODE

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 60 Command Details Initialize Command: <DEV/ICT_xx_yy'cr' Confirmation

Strona 76 - UTOMATIC/MANUAL MODE

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 61 B.6.3.3 BACKUP MODE This command allows the user to force a backup condition for m

Strona 77 - B.6.4.1 CONFIGURATION STATUS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 62 B.6.4.2 MAINTENANCE STATUS Command Details Maintenance Status: <DEV/RMS_&apos

Strona 78 - B.6.4.4 ALARM STATUS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 63 B.6.4.5 SUMMARY ALARM STATUS Summary alarm is set to Fault (FT) if any of the item

Strona 79 - B.6.4.5 SUMMARY ALARM STATUS

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 iv CHAPTER 2. INSTALLATION...

Strona 80 - ACKED UTILITY STATUS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 64 B.6.4.8 PACKED MAINTENANCE STATUS Packed Maintenance Status: <DEV/PACRMS_&apos

Strona 81 - B.6.5.1 TOTAL STORED ALARMS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 65 B.6.4.10 PACKED ALARM STATUS Packed Alarm Status: <DEV/PACRAS_'cr'

Strona 82 - B.6.5.3 LIST ALL ALARMS

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 66 B.6.5.3 LIST ALL ALARMS This command retrieves a list of the stored alarms. This

Strona 83 - B.7 ERROR PROCESSING

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 67 B.7 ERROR PROCESSING B.7.1 GENERAL ERRORS The following Error Responses may be gen

Strona 84 - Remote Control Rev. 0

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 68 B.8 CONVERTER REMOTE COMMAND SUMMARY Table 10. Remote Command Summary Utility C

Strona 85

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 69 Status Commands Paragraph Retrieve Configuration Status <DEV/RCS_'cr&a

Strona 86

UT4579 X-Band Up Converter MN/UT4579.IOM Remote Control Rev. 0 70 NOTES:

Strona 87 - C.1 APPLICATIONS

71 Appendix C. Theory of Operation Applications 71 RF Signal Conversion 72 Monitor & Control 74 C.1 APPLICATIONS This appendix contains a gene

Strona 88 - C.2 RF SIGNAL CONVERSION

UT4579 X-Band Up Converter MN/UT4579.IOM Theory of Operation Rev. 0 72 The "Daisy Chain" configuration is designed to chain the IF input a

Strona 89 - Theory of Operation Rev. 0

UT4579 X-Band Up Converter MN/UT4579.IOM Theory of Operation Rev. 0 73 5/10 MHzREF. OSC.IF INPUT(70 or 140 MHz)RF OUTPUT(7900-8400 MHz)MONITOR&C

Strona 90 - C.3 MONITOR & CONTROL

UT4579 X-Band Up Converter MN/UT4579.IOM Preface Rev. 0 v A.4.5 Redundancy Systems - Converter Removal...

Strona 91 - Troubleshooting

UT4579 X-Band Up Converter MN/UT4579.IOM Theory of Operation Rev. 0 74 C.3 MONITOR & CONTROL The Monitor & Control Assembly is designed to m

Strona 92 - D.2 MAINTENANCE TESTING

75 Appendix D. Maintenance and Troubleshooting Overview 75 Maintenance Testing 76 Spare 79 D.1 OVERVIEW This appendix is intended to provide proced

Strona 93 - D.2.3.1 PRIME POWER

UT4579 X-Band Up Converter MN/UT4579.IOM Maintenance and Troubleshooting Rev. 0 76 PowerSupplyReferenceOscillatorFineStepModuleSumLoopModuleMonitor

Strona 94 - D.2.3.7 TEMPERATURE FAULT

UT4579 X-Band Up Converter MN/UT4579.IOM Maintenance and Troubleshooting Rev. 0 77 D.2.2 TROUBLESHOOTING Converter operating problems can be identif

Strona 95 - D.3 SPARE

UT4579 X-Band Up Converter MN/UT4579.IOM Maintenance and Troubleshooting Rev. 0 78 D.2.3.3 RF CONVERTER MODULE IFLO LOCK DETECT: A fault (“FT”) indi

Strona 96

UT4579 X-Band Up Converter MN/UT4579.IOM Maintenance and Troubleshooting Rev. 0 79 D.2.4 CONVERTER I/O MODULES The Converter I/O Modules (IOM, or TS

Strona 97

UT4579 X-Band Up Converter MN/UT4579.IOM Maintenance and Troubleshooting Rev. 0 80 NOTES:

Strona 98 - Index Rev. 0

81 Index A About this Manual... ix Access Methods ...57 Addresses ...

Strona 99 - Units of Weight

UT4579 X-Band Up Converter MN/UT4579.IOM Index Rev. 0 82 O Offset Adjustment...52 Operation...

Strona 100 - 480 • 333 • 2161 FAX

METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0

Komentarze do niniejszej Instrukcji

Brak uwag