LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–23
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Operating point
Returns the maximum operating point of the unit along with its timestamp
Reply format:
MAXFET=sYYYC mmddyy hhmmss’cr’
MINFET=sYYYC mmddyy hhmmss’cr’
MAXPFT=sYYYC mmddyy hhmmss’cr’
MAXDTP=sYYYC mmddyy hhmmss’cr’
MAXHTS=sYYYC mmddyy hhmmss’cr’
MINHTS=sYYYC mmddyy hhmmss’cr’
MAXOST=sYYYC mmddyy hhmmss’cr’
MAXRFP=sZZ.ZZ mmddyy hhmmss’cr’
MINRFP=sZZ.ZZ mmddyy hhmmss’cr’
Where:
sYYYC is the temperature
sZZ.ZZ is the power
Note: not all LPODs have outside temperature monitor. In that case, MAXOST and MINOST will report XXXXX
XXXXXX XXXXXX
Example: <1/MOP?’cr’
>0001/mop=’cr’
MAXFET=+000C 010208 180729’cr’
MINFET=+000C 010208 180729’cr’
MAXPFT=+000C 010208 180659’cr’
MAXDTP=+000C 010208 180729’cr’
MAXHTS=+050C 010208 180729’cr’
MINHTS=+050C 010208 180729’cr’
MAXOST=XXXXX XXXXXX XXXXXX’cr’
MINOST=XXXXX XXXXXX XXXXXX’cr’
MAXRFP=+00.00 010208 180659’cr’
MINRFP=+00.00 010208 180659’cr’