CPA C-Band Indoor Solid-State Power Amplifier Revision 1
Front Panel Operation MN/CPA-IN.IOM
5–18
5.3.3.2 UTILITY: CID (Circuit ID)
Edit Circuit ID:(◄ ►,▲ ▼)
24 CHARACTER TST MESSAGE
Only the bottom line is available (24 characters). To edit the Circuit ID string: First, use the ▲▼
arrow keys to set the cursor position to the bottom line. Next, use the
◄ ► arrow keys to
select the character to be edited, and then use the ▲▼ arrow keys to change that character.
The following characters are available:
[Space] ( ) * + -, . / 0-9 and A-Z.
Compose the Circuit ID string, and press ENTER when done.
5.3.3.3 UTILITY: PowerMon
Forward Power Mon Offset
Reverse Power Mon Offset
This function allows you to calibrate (fine tune) the RF Power Monitor for a specific carrier
frequency. The RF Power Monitor is factory-calibrated at the CPA center frequency. You can
adjust (offset) the display level using this function.
Select Forward Power Mon Offset or Reverse Power Mon Offset using the ◄ ► arrow keys,
then, press ENTER.
UTILITY: PowerMon Forward Power Mon Offset
Forward RF Power Monitor
Offset = +5.8 dBm
Use the
◄ ► arrow keys to set the cursor position on the bottom line, and then edit the
numeric value using the ▲▼ arrow keys. The range is from -6.0 to +6.0 dBm, in 0.1 dBm
steps.
UTILITY: PowerMon Reverse Power Mon Offset
Reverse RF Power Monitor
Offset = -5.8 dBm
Use the
◄ ► arrow keys to set the cursor position on the bottom line, and then edit the
numeric value using the ▲▼ arrow keys. The range is from -6.0 to +6.0 dBm, in 0.1 dBm
steps.