CPA C-Band Indoor Solid-State Power Amplifier Revision 1
Front Panel Operation MN/CPA-IN.IOM
5–18
5.3.3.2 UTILITY: CID (Circuit ID)
Edit Circuit ID:(◄ ►,▲ ▼)
24 CHARACTER TST MESSAGE
Only the bottom line is available (24 characters). To edit the Circuit ID string: First, use the ▲▼
arrow keys to set the cursor position to the bottom line. Next, use the
arrow keys to
select the character to be edited, and then use the ▲▼ arrow keys to change that character.
The following characters are available:
[Space] ( ) * + -, . / 0-9 and A-Z.
Compose the Circuit ID string, and press ENTER when done.
5.3.3.3 UTILITY: PowerMon
Forward Power Mon Offset
Reverse Power Mon Offset
This function allows you to calibrate (fine tune) the RF Power Monitor for a specific carrier
frequency. The RF Power Monitor is factory-calibrated at the CPA center frequency. You can
adjust (offset) the display level using this function.
Select Forward Power Mon Offset or Reverse Power Mon Offset using the arrow keys,
then, press ENTER.
UTILITY: PowerMon Forward Power Mon Offset
Forward RF Power Monitor
Offset = +5.8 dBm
Use the
arrow keys to set the cursor position on the bottom line, and then edit the
numeric value using the ▲▼ arrow keys. The range is from -6.0 to +6.0 dBm, in 0.1 dBm
steps.
UTILITY: PowerMon Reverse Power Mon Offset
Reverse RF Power Monitor
Offset = -5.8 dBm
Use the
arrow keys to set the cursor position on the bottom line, and then edit the
numeric value using the ▲▼ arrow keys. The range is from -6.0 to +6.0 dBm, in 0.1 dBm
steps.