Operation C5/K1/K3 Integrated Satellite Terminal System
4–16 Rev. 0
SDT5200 "TYPE"
VER: X.X.X
FUNCTION SELECT
CONFIGURATION
CONFIGURATION
INTERFACE
TX CLOCK SOURCE TX CLOCK PHASE EXT-CLK FREQ BUFFER CLOCK
RX CLOCK PHASE B-BAND LOOP BACK
LOOP TIMING
TX TERRESTRIAL
SCT (INTERNAL)
EXT. CLOCK
TX Data Rate and EXT-CLK
FRQ must match or ASLT option
installed.
AUTO
NORMAL
INVERT
8kHz to 10MHz
1544.00 KHz (default)
RX (SATELLITE)
SCT (INTERNAL)
EXT. CLOCK
TX TERRESTRIAL
INSERT CLOCK
NORMAL
INVERT
ON
OFF
OFF
ON
TX/RX Data Rates must
match or ASLT option.
TX CODING
FORMAT
RX CODING
FORMAT
TX DATA FAULT RX DATA FAULT
NONE
AIS
DATA
Overhead only
NONE
AIS
DATA
Overhead only
TX 2047 PATTERN
OFF
ON
Overhead only
RX 2047 PATTERN
OFF
ON
Overhead only
ACCESS TO
SUBMENU
CONDITIONAL OR
OPTION-DEPENDENT
Parameter
Information
Key:
INTERFACE
LOOPBACK
OFF
ON
Overhead or Reed-Solomon only
BUFFER SIZE BUFFER CENTER
32 to 262144 BITS
(16 BIT STEPS)
1 to 99 ms
0 (BYPASS)
YES
NO
A
AMI
B8ZS
HDB3
AMI
B8ZS
HDB3
Figure 4-6. Configuration Interface Menu