MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–17
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Command or
Response to
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
(Instruction
Code and
Query
(Target to
Alarm Status
74 bytes (BDC),
64 bytes (BUC),
alphanumeric
Returns the Query the Alarm status of the unit
Example for MBT-4000B base:
<0001/RAS?{cr}
>0001/RAS={cr}
15VT1=OK{cr}
7V5T1=OK{cr}
5VLT1=OK{cr}
28VT1=OK{cr}
REFLD=OK{cr}
IICST=OK{cr}
LNAC1=OK{cr} (Note 2)
LNAC2=OK{cr} (Note 2)
LNAW1=OK{cr} (Note 3)
LNAW2=OK{cr} (Note 3)
LNAI1=OK{cr} (Note 4)
LNAI2=OK{cr}{lf} (Note 5)
Example for BUC/BDC:
<0001A1/RAS?{cr}
>0001A1/RAS={cr}
15VLT=OK{cr}
7V5LT=OK{cr}
5VOLT=OK{cr}
REFLD=XX {cr} (reserved for future use)
SYNLD=OK{cr}
HSTMP=OK{cr}
LNACR=OK{cr}{lf} (Note 1)
Notes:
1. LNACR will only appear for BDC.
2. FT reported if MAX current exceeded.
3. FT reported if LCW window current exceeded.
4. FT reported if EAM = 11 & Pin F of J9 High.
5. FT reported if EAM = 21 & Pin F of J8 High, not applicable to
(see Description of
Arguments for
details)