0BService Level Agreement (SLA) Revision 3
NetVue User Guide MN-NETVUE
5–10
5.2.5.2 Alarm Settings
See Figure 10Alarm Settings. Use Alarm Settings to define these parameters:
Alarm level the SLA must violate
Delay before the SLA indicates it has been violated
Minimum outage threshold for the SLA to trigger
Filter which alarms trigger SLA impact
Figure 10Alarm Settings
Violation Level sets the Alarm Level at which the SLA must start to indicate violations
Delay Time sets a delay period in seconds; after this delay, the SLA starts to indicate violations (e.g., for
backup delays)
Minimum Outage Threshold sets the minimum outage period before the SLA starts to indicate violations
Note: The duration of an alarm includes any delay time in effect. It does not include any minimum outage
threshold in effect.
Violation Settings set alarm filters or set significance weights for specific alarms.