DD240XR High-Speed Digital Demodulator User Interfaces
MN-DD240XR Rev. E 4-63
synthPLL(1),
inputLevel(2),
clockActivity(3),
carrierCommunication(4),
demodCommunication(5),
fpgaConfiguration(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
A bit field. On startup, the agent initializes these to a '0'B value.
"
::= { alarms 7 }
latchedMinorAlarms OBJECT-TYPE
SYNTAX BITS {
dataActivity(0),
buffUnderflow(1),
buffNearEmpty(2),
buffNearFull(3),
buffOverflow(4),
excClock(5),
excPllLock(6),
demodLock(7),
ifecLock(8),
ofecLock(9),
frameSync(10),
ebno(11),
terrEthDestIp(12),
terrEthLinkStatus(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
A bit field. On startup, the agent initializes these to a '0'B value.
"
::= { alarms 8 }
latchedCommonAlarms OBJECT-TYPE
SYNTAX BITS {
plus5V(0),
plus12V(1),
neg12V(2),
plus24V(3),
temperature(4),
lnbV(5),
demodHwFault(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
A bit field. On startup, the agent initializes these to a '0'B value.
1 indicates an alarm condition
temperature(3) is reserved and not currently updated
"
::= { alarms 9 }
clearLatchedAlarms OBJECT-TYPE
SYNTAX INTEGER {
ignore(0),
perform(1)
}
MAX-ACCESS read-write