DD240XR High-Speed Digital Demodulator User Interfaces
MN-DD240XR Rev. E 4-43
Opcode: <240Eh> Query Time
Response
<1>
<1>
<1>
Hour
Minute
Second
0 23
0 59
0 59
Opcode: <240Fh> Query Date
Response
<1>
<1>
<1>
Year
Month
Day
0 99
0 11
0 30
Opcode: <2550> Query Terrestrial Gig Ethernet Configuration
Response
<8>
<4>
<2>
<8>
<4>
<2>
<1>
<1>
<1>
<1>
Mac Address
IP Address
UDP Port
Destination Mac
Address
Destination IP
Address
Destination UDP
Port
Ethernet Mode
Block Aligned
FEC Column L
FEC Column D
Binary Value
Binary Address
0-32767
Binary Value
Binary Value
Binary Value
0 = UDP 1 = COP3 2 = COP3 FEC
0 = Aligned 1 = Not Aligned
Binary Value
Binary Value
Opcode: <2551> Query Terrestrial Gig Ethernet Status
Response
<1>
Ethernet Port
Status
0 = Down
1 = Unresolved
2 = 10 M Half
3 = 100 M Half
4 = 10 M Full
5 = 100 M Full