CLC-10 Comtech LPOD Controller Handheld Terminal M&C Accessory Revision 3
Setup MN-CLC10
2–4
2.2.2 CA-0020526 19-pin Circular Connector
The CA-0020526 Serial Interface Cable’s 19-pin circular connector features a keyed
configuration. Figure 2-6 shows the mating relationship between this connector and the ‘J6 |
COM1’ socket on the SSPA, or the ‘J1’ socket on the Redundant Loop Cable Assembly (CEFD P/N
CA-0020655 for Rx / Tx applications, or CA-0020657 for Tx-only applications).
Feature Description
1 Primary Alignment features
2 Secondary Alignment features
3 Sleeve Lock features
Figure 2-6. CA-0020526 19-pin Circular Connector
Follow these steps to install the CA-0020526 Serial Interface Cable’s male 19-pin circular
connector into the SSPA’s ‘J6 | COM1’ port or the 1:1 Redundant Loop Cable’s ‘J1’ receptacle:
Engage the primary and secondary alignment tabs on the male connector with the mating cutouts on
the female socket.
Push the male connector into the female socket.
Turn the male connector sleeve clockwise until the sleeve lock cutouts engage fully with the female
socket tabs and you hear a “click” sound.
2.2.2.1 Circular Connector Connection for Standalone Applications
For standalone configurations, the CA-0020526 Serial Interface Cable connects
directly between the CLC-10 and the SSPA.
Connect the CA-0020526 Serial Interface Cable’s 19-pin circular connector to the SSPA’s
‘J6|COM1’ port as per the steps described in Sect. 2.2.2, and as shown in Figure 2-7.
Figure 2-7. CLC-10 to SSPA Connection – Standalone Applications