
CiM-25/600 IP Enabled M&C Rev. 3
SNMP Interface CD/CIM25600.IOM
42
3.6 MAINTENANCE INTERFACE
The default network configuration settings are:
IP: 10.6.30.1
Admin Name: admin
Admin Password: 1234
The CiM-25 has been designed to allow a user to reset the unit back to the factory default
settings, change the IP Address, and verify the software version. Use the following
procedure to make these changes.
Perform the following steps:
1
Disconnect the CiM-25 from both the interfacing equipment and the Ethernet Network.
2
Connect the CiM-25 to the serial port of a PC using a cable defined below (null cable):
CiM-25 pin 2 to PC pin 3
CiM-25 pin 3 to PC pin 2
CiM-25 pin 5 to PC pin 5
2
3
5
DB9
2
3
5
DB9
To CiM-25 Device
(M/F Depending on Unit)
To Computer
(Usually Female)
Figure 1. Null Cable Diagram
3
Power the CiM-25 using the Power Jack connector and an external 5 Vdc power supply.
4
Using a Serial Communication application such as Terminal, ProComm, etc., configure the
PC’s serial port to:
Baud: 19200
Data rate: 8-N-1
Use the procedures in following sections to:
Reset to factory network defaults.
Change network IP Address.
Verify software version.
Change MAC Address.
Change Serial Number.
Komentarze do niniejszej Instrukcji