Comtech EF Data KST-2000B Dokumentacja Strona 247

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 258
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 246
CDM-600 Satellite Modem Revision 7
ODU Operation MN/CDM600.IOM
D–11
D.2.20 (ODU,ENABLE,1:1,CSAT#1, ALARMS) STORED-ALARMS
(ODU,ENABLE,1:1,CSAT#2, ALARMS) STORED-ALARMS
(ODU,ENABLE,STANDALONE CSAT, ALARMS) STORED-ALARMS
As the stored events are being read, the screen will show:
READING STORED FAULTS..... PLEASE WAIT
Then, the Stored Alarms screen will be shown. An example is shown below:
STORED ALARMS: CLEAR-ALL: NO (NO,YES)
IF #84: 10/14/04 12:52:08 POWER ON
Use the [] or [] keys to select between the log entries and the CLEAR-ALL option.
With the cursor on the entry number, use the [] or [] keys to view through the entries.
Up to 99 entries are stored. Each entry shows:
the entry type: IF = information, FT = fault, OK = fault cleared
the entry number – 00 though 99
the date (international format)
the time
a description of the fault/information
To clear the Stored Alarms Log, select YES in the CLEAR-ALL option and press
ENTER.
D.2.21 (ODU,ENABLE,1:1,CSAT#1) INFORMATION
(ODU,ENABLE,1:1,CSAT#2) INFORMATION
(ODU,ENABLE,STANDALONE CSAT) INFORMATION
INFO: MODEL TX RX MISC LNA
Use the [] or [] keys to select the type of information to view, then press ENTER.