Comtech EF Data Vipersat SLM-5650A Podręcznik Użytkownika Strona 102

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 320
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 101
VMS Network Configuration
3-30 VMS User Guide
Figure 3-35
Create Pool dialog
3. The Center Frequency setting will reflect the Transponder frequency value
corresponding to the point where the mouse was clicked to create the pool.
Correct this setting to the desired value for this pool, and adjust the
Bandwidth to the correct width.
Click OK and the new pool will appear (figure 3-36).
Figure 3-36
New Bandwidth Pool
4. Repeat the previous steps to create additional bandwidth pools.
5. Right-click on the inbanded subnet in the Subnet Manager View and select
Resize Uplink Carrier from the drop-down menu (figure 3-37).
The Resize Uplink dialog will open, allowing a New Bitrate to be specified.
The bit rate shown is equal to the current bit rate; in this case, the STDMA
channel rate.
6. Click on OK to close the dialog and initiate a switch.
Przeglądanie stron 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 319 320

Komentarze do niniejszej Instrukcji

Brak uwag