CiM-550 IP Enabled Satellite Modem Rev. 2
SNMP interface CD/CIM550.IOM
259
13.5.1.13 ODU RX PARAMETERS
Table 13-47. ODU Rx Parameters OIDs
OID
Description
OduRxFequency
Receive frequency in KHz. Can be between 3,625,000 KHz
and 14,100,000 KHz.
oduRxAttenuation
Receive attenuation. Can be between 0..2500 in 0.01dB
where 0=0.00dB to 2500=25.00dB.
oduRxMute
Receive mute. Can be set to:
0 Disabled
1 Enabled
oduRxSlopeMode
Receive slope mode. Can be set to:
0 Manual
1 Calibrated
oduRxSlopeValue
Receive slope value. Can be between 0..10 in 0.1, where
0=0.0 to 10=1.0.
oduRxGainOffset
Receive gain offset. Can be between -400 and 0 in 0.01 dB,
where 0=0.00 dB to -400 = -4.00dB