MD2401 L-Band Multi Demod Installation and Operation Manual User Interfaces
MN-MD2401 4–9
Revision 7
Figure 4-6. Interface Controls Menu
EXC Clock (MHz): {N/A}
Reference Source: {INTERNAL, EXTERNAL}
Allows the user to select the Frequency Reference Source.
Ext Ref Frequency (MHz): {Selectable}
Allows the user to select the Frequency Reference Source.
Buffer Byte Size: {nnnn Bits}
Allows the user to select the byte size Buffer
Buffer/msec: {0 - 32 msecs}
Allows the user to set the Doppler Buffer Size in msec.
Buff Clk Select: {RXSAT, SCTE, SCT}
Shows the current active buffer clock source.
Buff Clk Polarity: {NORMAL, INVERTED}
Allows the user to select the Buffer Clock Polarity for the Rx
Terrestrial Clock relative to the Rx Data.
RX Ckt ID: Allows the user to create an ID of the RX circuit.
Eb/No Thsd: Allows the user to select the low end threshold alarm limits.