Operation SDM-650B Satellite Modem
4–16 Rev. 5
4.1.4.3 Select Faults
Refer to Table 4-4.
The Faults level is accessible from the Select menu. Faults are similar to monitor
functions, they display the current fault status of the group being displayed.
Use
[] and [] to move between the fault groups:
Mod_Flts (modulator faults)
Dmd_Flts (demodulator faults)
Ceq_Flts (common equipment faults)
The current fault status is displayed on line 2 of the display in real time. Fault status is
displayed as a “+” or a “-” for each parameter monitored.
“+” indicates that a fault exists.
“-” indicates that no fault exists.
To display labels for individual faults, press [ENTER]. Use
[] and [] to move the
flashing cursor to the fault to be identified. The label for that fault is immediately
displayed on line 1 of the display.
[CLEAR] can be used to exit this level of operation and return to the previous level.
The following sections outline the faults monitored and displayed in each group.